Introduction:
Often there are requirements like having a common large tasklist for a category of equipments and choosing the operations selectively into the Maintenance Order depending upon the equipment specifications on which the order is being made.
Let me explain with an example:.
Suppose there are 100 motors falling into 6 categories as under:
SN | Type | Capacity (KW) | Population |
1 | Squirrel Cage Induction (SQI) | 5.5 | 20 |
2 | ‘’ | 7.5 | 30 |
3 | ‘’ | 11.5 | 5 |
4 | Slip Ring (SLR) | 5.5 | 10 |
5 | ‘’ | 7.5 | 15 |
6 | ‘’ | 11.5 | 20 |
Now the operations to carry-out the work on these machines vary with different ratings (specifications), often due to the variance in the amount of work involved.
We can have all operations of such 6 categories of 100 equipments in a single large tasklist, yet use in maintenance orders created on these equipments.
i.e., While creating the maintenance order, system would choose only those operations from the tasklist which are relevant to the equipment on which the order is being made .
Such tasklist is called a ‘Configurable Tasklist’.
Let’s assume the common large tasklist (General Maintenance tasklist) we have for all these motors is the one shown here, which is to be configured.
Image may be NSFW.
Clik here to view.
Now let us see how, the tasklist is configured.
1. Create the characteristics (CT04)
Create a capacity characteristic for ‘MOTOR_CAP’.
Image may be NSFW.
Clik here to view.
Now, specify the values and save.
Image may be NSFW.
Clik here to view.
Similarly create a Type characteristic for ‘MOTOR_MDL’.
Image may be NSFW.
Clik here to view.
Specify the values and save.
Image may be NSFW.
Clik here to view.
2. Create a class (CL02) ,
Say class ‘MOTOR_TYPES’ (type '300'),
Assign characteristics created above and save.
Image may be NSFW.
Clik here to view.
Image may be NSFW.
Clik here to view.
3. Object dependencies (CU01)
Create object dependencies as below:
Here dependency ‘SQI5.5’ illustrated.
Image may be NSFW.
Clik here to view.
Go to ‘Dependency Editor’ and specify the dependency as shown here.
Image may be NSFW.
Clik here to view.
Come back to CU01 initial screen and set the Status to 'Released'
Similar dependencies to be made for all combinations of Capacity and Type, viz.,
SQI7.5,
SQI11.5,
SLR5,5,
SLR7.5 and
SLR11.5
Here another illustration is given for dependency ‘SQI7.5’.
Image may be NSFW.
Clik here to view.
Image may be NSFW.
Clik here to view.
Come back to CU01 initial screen and set the Status to 'Released'
4. Tasklist configuration profile (CU41)
Create a Configuration Profile selecting General Maintenance Tasklist.
Image may be NSFW.
Clik here to view.
Create as shown below. (Do not give values in the value fields) and
Do not forget to select the 'Std Class' check-box.
Image may be NSFW.
Clik here to view.
5. Assign the class to equipments (IE02).
Assign class ‘MOTOR_TYPES’ to the these 100 equipments, with respective characteristic values as shown below:
(Go to 'Class Overview' screen and assign)
Image may be NSFW.
Clik here to view.
6. Assign the dependencies to tasklist operations (IA06):
As shown here:
Image may be NSFW.
Clik here to view.
Image may be NSFW.
Clik here to view.
Assign dependencies to all the tasklist operations which are equipment specific, in a similar way.
Leave the common operations untouched.
Now, the configuration is complete.
Let’s see what effect this exrecise has while selecting tasklist in an order (IW31/32).
Menu : Extras --> Tasklist selection --> Direct Entry
In the popup, give the Tasklist group and counter, as shown.
Image may be NSFW.
Clik here to view.
In the resulting screen, give the characteristic values of the order equipment,
Image may be NSFW.
Clik here to view.
Click ‘Back’ and go to the operations tab.
Here is the result:
Image may be NSFW.
Clik here to view.
System has chosen the relevant dependency operation (0040) and two operations, where no dependencies were specified. (0070, 0080).
This work can be extended to a tasklist of 100's of operations covering 1000s of equipments.
In my experience, very common application has been in Repair shops where equipments like Motors are repaired. Here very few numbers of Configurable tasklists are maintained covering 1000s of motors.
_________________________________________________________________________________________________________________________________